MICRO-PROCESSOR CONTROLLED RECTIFIERS
DC chargers are ideal for transformer energy distribution centers, gas oil energy distribution centers, natural gas energy distribution centers, mining industry security and lighting, building automation systems and for special telecommunication applications.
• They can be used either as battery charger or DC power supply
• Micro processor controlled design,
• Adaptable output current and voltage
• Adjustable timer for boost charging
• Separate output connections for the battery and load,
• High, low and reverse voltage protection
• Overheat and short circuit protection,
• Parallel or series connection is possible,
• Thyristor controlled design with isolation transformer,
• Reset button and display
MICRO PROCESSOR CONTROLLED RECTIFIER TECHNICAL SPECIFICATIONS |
STANDARDS |
EN 50091-1 security and EN 50091-2 EMC |
DESIGN |
Micro processer thyeristor controlled board, isolation transformer |
INPUT |
VOLTAGE |
Single phase 220 VAC Three phase 380 VAC 3 FAZ |
VOLTAGE RANGE |
± % 15 |
FREQUENCY |
50 Hz ± %5 |
POWER FACTOR |
> 0,8 |
PROTECTIONS |
Overheat, overload, high voltage |
OUTPUT |
STANDARD OUTPUT VOLTAGE |
12, 24, 48, 110, 220 VDC |
STANDARD OUTPUT CURRENTS |
10, 15, 20, 30, 40, 50, 60, 100, 150, 200 Ampere |
DISCHARGE VOLTAGE |
10 VDC / per each battery |
FREQUENCY |
Equal to input frequency |
POWER FACTOR |
> 0,8 |
PROTECTIONS |
High voltage, reverse voltage, short circuit |
OUTPUT CURRENT SET UP |
by means of digital display |
MAXIMUM CURRENT |
% 110 |
BOSST CHARGING VOLTAGE |
(Standard voltage value)x2 |
BOSST CHARGING TIME |
0-600 min |
BOSST CHARGING |
1 dk |
DISPLAY AND PANEL Dry contact, reset button |
DISPLAY |
Output voltage and current |
BUTTONS |
Standard charge, boost charge, boost charging time, current buttons, |
WARNINGS |
WARNINGS / LED |
Standard charge, boost charge, output failure, over load, over heat |
WARNINGS / VOICE |
Every 2 seconds during failure |
LOW BATTERY |
When a battery voltade drops under 10 VDC ( Led warning ) |
DEVICE FAILURE |
High or low DC, output failure, over heat, no mains, output short circuit |
|
WINDINGS (TRANSFORMER) |
Glass fiber coated copper or aluminum bobbin wire |
EFFICIENCY |
> % 85 ( at full load ) |
GROUNDING |
Transformers and metal body |
CABLE CONNECTIONS |
Rail terminal |
PROTECTION CLASS |
IP 54 |
MAIN BODY |
Metal frame |
ISOLATION CLASS |
1.class, H 180 °C |
THERMAL CLASS |
Ta 60 °C / H |
IMPREGNATION |
According to insulation class, protection against moisture, lesser sound level |
COOLING |
Natural |
NOISE LEVEL |
˂ 50 dB ( 1 meter ) |
HUMIDITY |
%90 non-condensing ( DIN 40040 ) |
OPERATING ALTITUDE |
0 - 2000 m |
AMBINET TEMPERATURE |
- 10 °C ..... + 50 °C |
STORING TEMPERATURE |
- 20 °C ..... + 70 °C |
|
|
|