top of page

THREE-PHASE ISOLATION TRANSFORMERS

omsan_batch2_2.png
omsan_batch2_0.png

Three-Phase Isolation Transformers


Engineering-Oriented Power Quality for Critical Industrial Applications

​

Omsan three-phase isolation transformers are specifically designed to provide true galvanic isolation, high power quality, and long-term operational reliability in demanding industrial environments.

By completely separating the primary and secondary systems, Omsan transformers effectively reduce the following effects:

​

  • Common mode and differential mode noise

  • Voltage transients and switching-related distortions

  • Ground loop currents

  • Electromagnetic interference (EMI/RFI)

​

As a result, stable voltage conditions and uninterrupted operation are ensured, even in facilities with high harmonic distortion and sensitive loads, such as CNC machines, automation systems, and data infrastructure.

​​

Not a Standard, but an Engineered Product

 

Omsan transformers are not catalog products; each is designed specifically for the application. Design parameters are determined according to actual operating conditions:

​

  • Measured load profile and duty cycle

  • Total Harmonic Distortion (THD) levels

  • Ambient temperature and thermal conditions

  • Cooling performance requirements

  • System grounding structure

​

This Approach Offers The Following Advantages:

​

  • Lower thermal stress under harmonic loads

  • Increased insulation life

  • Higher system reliability in continuous operation

​​

Performance Advantages

​

  • Full galvanic isolation between input and output

  • High attenuation against electrical noise and interference

  • Design suitable for operation under non-linear loads.

  • Stable thermal performance in continuous operation

  • High efficiency with low-loss core design

  • High mechanical strength suitable for industrial environments

​​

Technical Specifications

​

  • Power Range: 0.1 kVA – 2000 kVA

  • Frequency: 50 / 60 Hz

  • Voltage Levels: Fully customizable

  • Insulation Class: F / H (IEC 60085)

  • Temperature Rise: 80K / 100K

  • Cooling: AN / AF

  • Protection Class: IP00 – IP23 (up to IP55 optional)

  • Vector Group: Dyn, Yyn, Dd, or application-specific

  • Efficiency: Up to 99%

  • ​

Standards and Compliance:

​

  • IEC 60076

  • EN standards

  • CE conformity

​

Production and Process Quality

​

Omsan transformers are manufactured with controlled and repeatable production processes:

​

  • Precise core arrangement to reduce losses and noise

  • Controlled winding voltage for insulation integrity

  • Multi-layer insulation for long-term dielectric strength

  • Vacuum Pressure Impregnation (VPI) against moisture and vibration

  • Mechanical reinforcement for transport and operating durability

​

Testing and Verification

​

All products undergo 100% routine testing in accordance with IEC standards:

​

  • Winding resistance

  • Voltage ratio and vector group verification

  • Impedance measurement

  • Loss measurements under load and without load

  • Insulation resistance and dielectric tests

​

Optional type tests:

​

  • Temperature rise test

  • Partial discharge measurement

  • Lightning impulse test

​

Each transformer is delivered with complete test documentation and traceability.

​

Proven Performance in the Field

​

Omsan transformers are actively used in industrial facilities with high harmonic content and critical loads:

​

  • Reliable operation in CNC and automation systems

  • High durability in continuous-duty applications

  • Long service life with low maintenance requirements

​

Warranty and Risk Reduction

​

Omsan offers a warranty of up to 10 years, supporting the following advantages:

​

  • Lower life-cycle cost

  • Reducing unplanned downtime

  •  

    Long-term operational security

    ​

What Makes Omsan Different

​

Omsan positions itself not as a standard transformer supplier, but as an engineering solution partner:

​

  • Application-specific design (not a catalog product)

  • Fast engineering support and short delivery times

  • Direct communication with design engineers

  • Optimized solutions for harmonic-intensive and sensitive systems

  • Competitive cost-performance balance without compromising quality

​​

Application Areas

​

  • Industrial production facilities

  • CNC machines and machine tools

  • Automation and robotic systems

  • Data centers and IT infrastructure

  • Renewable energy systems

  • Marine and rail applications

​

Conclusion

​

Omsan isolation transformers are designed to protect, stabilize, and extend the lifespan of your electrical systems. They are not just components; they are critical parts of power quality and system reliability.

​

Request Engineering Support

​

​Contact us for a project-specific assessment.

​​​

ChatGPT Image 28 Apr 2026 12_02_55.png
omsan_result_3_edited.jpg
Çapa 1

Türkiye   Head Office & Factory

Saray Mahallesi 205. Cadde no 4/3 KahramanKazan Ankara / Türkiye 444 4 509 info@omsantrafo.com.tr

 

Our Customer Representatives in

Marmara Sales 

Turan Karabulut

Tel: 0501 622 42 79

Mail : Turan@omsantrafo.com.tr

Istanbul:   +90535 050 14 35 hamit@omsantrafo.com.tr

Izmir:   +90532 280 27 09 zehra@omsantrafo.com.tr             

Germany                                         

Our Sales Office                    

Centrum 8d 92353 Postbauer-Heng

+49 172 703 08 84  

a.doenmez@omsantrafo.com.tr

                       

France                                        

Our Sales Office                    

59, rue louis le grand 39140 Bletterans/France

+33 6 76 68 40 08   ulas@omsantrafo.com.tr

                       

Our Global Customer Representatives :

+90 535 306 02 03 / Yaren Menekşe

+90 532 568 51 47 / Cemil Cömert

global@omsantrafo.com.tr

                       

bottom of page